Skip
Live free-market rates
USD272,500▲ 0.37٪EUR306,670▲ 0.56٪AED74,778▲ 0.6٪CNY41,000▲ 0.29٪TRY5,470▲ 0.55٪
Market & prices →
Free engineering tool

RAID capacity calculator

Enter disk count and size and pick a RAID level to instantly see real usable space, how many disks can fail and the rebuild risk.

Instant, in your browserNo sign-upFormulas shown

1Disks

Unit
Disk labels normally use TB (decimal)

2RAID level

3Rebuild risk

HDD under load: 50–150; SSD far higher

Result

RAID 6
Usable capacity—TB
Efficiency—
—Raw capacity (TB)
—Disk failures tolerated
—Write penalty
—Approx. rebuild time
RAIDUsable TBEff.Tolerance
Get disk & storage quotes

RAID capacity formulas

Below, n is the number of active disks (excluding spares), s the size of each disk and g the number of span groups in RAID 50/60.

RAID 0 : usable = n × s tolerance 0 (min 2 disks) RAID 1 : usable = s tolerance n − 1 (min 2) RAID 5 : usable = (n − 1) × s tolerance 1 (min 3) RAID 6 : usable = (n − 2) × s tolerance 2 (min 4) RAID 10 : usable = (n ÷ 2) × s tolerance 1 (up to n/2) (min 4, even) RAID 50 : usable = (n − g) × s tolerance 1 per group (min 3 per group) RAID 60 : usable = (n − 2g) × s tolerance 2 per group (min 4 per group) efficiency = usable ÷ (n × s) 1 TB = 10¹² B = 0.9095 TiB

Rebuild risk and URE

When a disk fails, the controller must read every surviving disk in the group in full to rebuild the replacement. Vendors specify an unrecoverable read error rate; the chance of hitting at least one during that read is approximately:

bits_read = data read during rebuild (TB) × 8 × 10¹² P(≥1 URE) = 1 − e^(−bits_read ÷ URE) rebuild_time ≈ disk size ÷ rebuild speed

In RAID 5 such an error during a rebuild can lose some or all data; RAID 6 still has a parity layer to correct it. The model is conservative — the URE spec is an upper bound and healthy disks usually do better — but it is very useful for comparing levels and deciding about large disks.

Selection tips

  • RAID 10 gives the best performance for databases and random writes (write penalty 2).
  • RAID 6 balances space and safety for archives and file servers on large disks.
  • RAID 50/60 shorten rebuilds on big arrays by keeping each group small.
  • On large arrays keep at least one hot spare so a rebuild starts immediately.
FAQ

Questions about this calculation

Why does the OS show less space than the disk label?

Disk makers use decimal units (1 TB = 10¹² bytes) while most operating systems show binary units (1 TiB = 2⁴⁰ bytes). One TB ≈ 0.91 TiB, so an 8 TB disk shows ≈ 7.28 TiB. Filesystem and RAID metadata take a little more.

Is RAID 5 still OK for large disks?

For large spinning disks (multi-TB), usually not. Rebuilds take hours to days with no redundancy left; one unrecoverable read error or a second failure means data loss. RAID 6 or RAID 10 is the safer choice.

Is RAID a backup?

No. RAID only protects against disk hardware failure — not deletion, ransomware, controller failure or fire. Always keep independent backups (ideally the 3-2-1 rule).

From numbers to equipment

Get a quote for equipment that matches this result

Attach the result to your request and receive comparable offers from our partner network and international suppliers.

Request a quote$1 = 272,500 Toman